Supplying you with customized flame retardant rs485 databus cables lszh sheath, it is one of the reliable flame retardant rs485 databus cables lszh sheath manufacturers and suppliers, welcome to wholesale our products at good price from our factory.
Flame Retardant RS485 Databus Cables
Application: |
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable. |
Standard: |
Basic design to EIA/TIA 485 |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
60V
CABLE CONSTRUCTION
Multipair RS 485 Overall Screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Overall screen: Aluminum/polyester tape with tinned copper drain wire.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)
Multipair RS 485 Overall Double Screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Overall screen: Aluminium/polyester tape+copper wire braid.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
Multipair RS 485 Individual & Overall screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation. Cabling: Pairs are cabled together in concentric layers. Individual Screen: Individual aluminium/polyester tape. Overall Screen: Copper wire braid.
outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
Multipair RS 485 Overall Screened Databus Cable
Conductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Foam PE or foam skin PE.
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.
Cabling: Pairs are cabled together in concentric layers.
Overall Screen: Copper wire braid.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -20°C - +90°C
Temperature range during installation (mobile state): -5°C - +60°C
Minimum bending radius: 8 x Overall Diameter
Electrical Properties
Dielectric test |
1000 V r.m.s. for 5' (core-core) |
1000 V r.m.s. for 5' (core-screen) |
|
Impedance |
120Ω |
capacitance |
45 nF/km conductor to conductor |
90 nF/km conductor to shield |
CONSTRUCTION PARAMETERS
Multipair RS 485 Overall Screened Databus Cable
RE-02Y(St)H / RE-02YS(St)H
No.of pair x |
Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
mm2 |
No/mm |
mm |
mm |
mm |
kg/km |
|
1 |
0.22 |
7/0.2 |
0.55 |
0.40 |
4.0 |
21 |
2 |
0.22 |
7/0.2 |
0.55 |
0.40 |
7.1 |
42 |
4 |
0.22 |
7/0.2 |
0.55 |
0.40 |
8.3 |
68 |
1 |
0.50 |
16/0.2 |
0.55 |
0.40 |
4.6 |
32 |
2 |
0.50 |
16/0.2 |
0.55 |
0.40 |
8.2 |
68 |
4 |
0.50 |
16/0.2 |
0.55 |
0.40 |
9.8 |
115 |
1 |
0.75 |
24/0.2 |
0.55 |
0.40 |
5.1 |
40 |
2 |
0.75 |
24/0.2 |
0.55 |
0.40 |
9.1 |
84 |
4 |
0.75 |
24/0.2 |
0.55 |
0.40 |
10.9 |
144 |
1 |
1.00 |
30/0.2 |
0.55 |
0.40 |
5.2 |
49 |
2 |
1.00 |
30/0.2 |
0.55 |
0.40 |
9.5 |
105 |
4 |
1.00 |
30/0.2 |
0.55 |
0.40 |
11.2 |
182 |
Multipair RS 485 Overall Double Screened Databus Cable
RE-02Y(St)CH / RE-02YS(St)CH
No.of pair x |
Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
mm2 |
No/mm |
mm |
mm |
mm |
kg/km |
|
1 |
0.22 |
7/0.2 |
0.55 |
0.40 |
4.5 |
34 |
2 |
0.22 |
7/0.2 |
0.55 |
0.40 |
7.5 |
67 |
4 |
0.22 |
7/0.2 |
0.55 |
0.40 |
8.8 |
97 |
1 |
0.50 |
16/0.2 |
0.55 |
0.40 |
5.1 |
48 |
2 |
0.50 |
16/0.2 |
0.55 |
0.40 |
8.7 |
97 |
4 |
0.50 |
16/0.2 |
0.55 |
0.40 |
10.3 |
150 |
1 |
0.75 |
24/0.2 |
0.55 |
0.40 |
5.6 |
57 |
2 |
0.75 |
24/0.2 |
0.55 |
0.40 |
9.7 |
116 |
4 |
0.75 |
24/0.2 |
0.55 |
0.40 |
11.4 |
182 |
1 |
1.00 |
30/0.2 |
0.55 |
0.40 |
5.7 |
67 |
2 |
1.00 |
30/0.2 |
0.55 |
0.40 |
10.0 |
138 |
4 |
1.00 |
30/0.2 |
0.55 |
0.40 |
11.8 |
222 |
Multipair RS 485 Individual & Overall screened Databus Cable
RE-02Y(St)H pimf / RE-02YS(St)H pimf
No.of pair x |
Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
mm2 |
No/mm |
mm |
mm |
mm |
kg/km |
|
1 |
0.22 |
7/0.2 |
0.55 |
0.40 |
4.4 |
35 |
2 |
0.22 |
7/0.2 |
0.55 |
0.40 |
7.5 |
69 |
4 |
0.22 |
7/0.2 |
0.55 |
0.40 |
8.8 |
106 |
1 |
0.50 |
16/0.2 |
0.55 |
0.40 |
5.0 |
49 |
2 |
0.50 |
16/0.2 |
0.55 |
0.40 |
8.7 |
100 |
4 |
0.50 |
16/0.2 |
0.55 |
0.40 |
10.3 |
159 |
1 |
0.75 |
24/0.2 |
0.55 |
0.40 |
5.5 |
58 |
2 |
0.75 |
24/0.2 |
0.55 |
0.40 |
9.7 |
119 |
4 |
0.75 |
24/0.2 |
0.55 |
0.40 |
11.2 |
174 |
1 |
1.00 |
30/0.2 |
0.55 |
0.40 |
5.6 |
68 |
2 |
1.00 |
30/0.2 |
0.55 |
0.40 |
10.0 |
142 |
4 |
1.00 |
30/0.2 |
0.55 |
0.40 |
11.8 |
234 |
Multipair RS 485 Overall Screened Databus Cable
RE-02YCH / RE-02YSCH
No.of pair x |
Nominal Cross Sectional Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
mm2 |
No/mm |
mm |
mm |
mm |
kg/km |
|
1 |
0.22 |
7/0.2 |
0.55 |
0.40 |
4.3 |
31 |
2 |
0.22 |
7/0.2 |
0.55 |
0.40 |
7.3 |
61 |
4 |
0.22 |
7/0.2 |
0.55 |
0.40 |
8.5 |
91 |
1 |
0.50 |
16/0.2 |
0.55 |
0.40 |
4.9 |
44 |