Technical specifications
Receiving part
•voltage channel: ±32V(24 bitA/D)
accuracy: as Vp≥5mV, ±0.2% ±1 character as 0.1mV≤Vp<5mV, ±1% ±1 character
•Input impedance: >50MΩ
•Apparent polarization accuracy: ±1%±1character
•SP compensation range: ±10V
•Current channel: 6A(24bitA/D
Transmitter part
•maximium power: 7200W
•maximium supply voltage: ±1200V
•maximium supply current: ±6A
Deep geophysical equipment groundwater detector 1D IP sounding:
ID | AB/2(M) | MN/2(M) | K |
1 |
1.5 | 0.5 | 12.566371 |
2 | 2.5 | 0.5 | 23.561945 |
3 | 3.5 | 0.5 | 37.699112 |
4 | 4.5 | 0.5 | 54.977871 |
5 | 5.5 | 0.5 | 40.5678 |
http://www.cqtopgeo.com/